Interrater Reliability of the Mandibular Induction Test

Item

Elisabeth Nauschnegg. n.d. “Interrater Reliability of the Mandibular Induction Test.”, Osteopathic Research Web, accessed May 29, 2026, https://www.osteopathicresearch.org/s/orw/item/4463

Title
en Interrater Reliability of the Mandibular Induction Test
Description
de Wissenschaftlicher
Hintergrund:

Das Ziel der
vorliegenden Arbeit war es, die Interrater-Reliabilität des Induktionstests am
Os mandibulare zu untersuchen. Dieser Test dient der qualitativen Beurteilung
der Beweglichkeit der Mandibula in Außen- und Innenrotation. Bislang liegen
noch keine Studien zur Reliabilität und Validität dieses Testverfahrens vor.

 

Methodik:

Bei der
vorliegenden Studie handelt es sich um eine Interrater-Reliabilitätsstudie.
Hierbei wurde der Induktionstest Os mandibulare an 42 Proband_innen (26 weiblich, 16 männlich) durchgeführt. Die
Bewertung erfolgte anhand eines standardisierten Bogens mit drei Kategorien
(„unauffällig“, „auffällig rechts“, „auffällig links“). Um die Übereinstimmung
zwischen den beiden Testerinnen zu beurteilen, wurde der Cohens-Kappa-Koeffizient
berechnet.

 

Ergebnisse:

Je nach
Auswertungskategorie lagen die Cohens-Kappa-Werte zwischen κ = 0,25 und κ =
0,48. Für eine substanzielle Übereinstimmung wurde jedoch ein Wert von κ ≥ 0,61
nach Landis und Koch (1977, S. 165) angestrebt. Die höchste Übereinstimmung wurde in der symptomatischen
Subgruppe festgestellt (κ = 0,48).

 

Conclusio:

Die Übereinstimmung
zwischen den Testerinnen ist als mäßig bis mittelmäßig zu bewerten. Demnach
zeigen die Ergebnisse, dass dieser Test derzeit nur eingeschränkt in der
klinischen Praxis eingesetzt werden kann. Aus diesem Grund sind weitere Studien
zur Interrater-Reliabilität mit größeren Stichproben sowie zur
Intrarater-Reliabilität und zur Validität empfehlenswert.

 

Stichworte:

Interrater-Reliabilität,
Induktionstest, passiver Bewegungstest, Os mandibulare, Osteopathie
Alternative Title
de Interrater-Reliabilität des Induktionstests Os mandibulare
Creator
Elisabeth Nauschnegg
personal mailbox
e.nauschnegg@gmx.at
Abstract
en Background:

The aim of
this study was to investigate the interrater reliability of the induction test
of the mandible. The test
was used for the qualitative assessment of mandibular mobility in external and
internal rotation. So far, no studies have been published on the reliability
and validity of this test.

 

Research design and method:

This study was conducted as an interrater reliability
study. The induction test was performed on 42 participants (26 female and 16
male). The assessment was completed using a standardized form with three
categories ("normal", "right abnormal" and "left abnormal").
Cohen’s kappa coefficient was calculated to measure the agreement between the
raters.

 

Results:

The kappa values ranged between κ = 0.25 and κ = 0.48 depending on the evaluation category. According to Landis and
Koch (1977, S. 165), a value of κ ≥ 0.61 was aimed for substantial agreement. The
highest agreement was found in the symptomatic subgroup (κ = 0.48).

 

Conclusion

The
agreement between the testers was rated as fair to moderate. The results
indicate that this test can currently only be used to a limited extent in
clinical practice. Therefore, further studies with larger samples, as well as
investigations of intrarater reliability and validity, are recommended.

 

Keywords:

Interrater reliability, induction test, passive motion
test, mandible, osteopathy
Date Accepted
2025-11-09 22:53:35
Date Submitted
2026-05-21
Type
osteo_thesis
Language
German
owner
Elisabeth Nauschnegg
Subject
Interrater-Reliabilität, Induktionstest, passiver Bewegungstest, Os mandibulare, Osteopathie
Item sets
Thesis

Elisabeth Nauschnegg. n.d. “Interrater Reliability of the Mandibular Induction Test.”, Osteopathic Research Web, accessed May 29, 2026, https://www.osteopathicresearch.org/s/orw/item/4463